INTRODUCTION
Minimally invasive devices and procedures are fast becoming the largest growth segment of the medical and dental device industry. When compared to traditional approaches, they require less anesthesia, shorten surgical and recovery times, reduce patient risk, and can offer significant cost savings. Over time, we have witnessed the research and development of smaller and smaller components. Mini-dental implants dramatically improve the quality of the outcomes for patients seeking maxillary and mandibular overdenture treatment.
Small-diameter implants (1.8 to 3.0 mm) also differ from their full-sized counterparts in several ways. Their configuration allows for a more conservative placement protocol without involving tissue flaps or tapping procedures, resulting in minimal trauma for the bone and the gingival tissues. Mini-dental implants’ size also allows the clinician to place them in ridges that might not otherwise be suitable for full-sized implants.
Once these mini-dental implants are firmly seated in place in intimate contact with bone, they can be immediately loaded with no lengthy waiting period or second-stage surgery.
The following case report will demonstrate the protocol for the placement of small-diameter implants, and the subsequent effects on the new prostheses.
CASE REPORT
Diagnosis and Treatment Planning
A male in his late 70s presented to our office; he was frustrated with the look and fit of his upper and lower dentures (Figure 1). Most importantly, he complained that his lower denture was nonretentive and nonfunctional, always falling out when speaking or while eating. He had been a denture wearer for the last 25 years, resulting in excessive resorption of the mandible.
Figure 1. Existing dentures were approximately 17 years old. | Figure 2. New upper and lower dentures. |
Figure 3. Lower edentulous ridge, in preparation for mini-dental implant placement. | Figure 4. Inclusive Mini Dental Implants (Glidewell Direct) in packages and ready for placement. |
The patient suffered from hypertension, which was controlled with medication.
The first phase of treatment would consist of having a new set of upper and lower dentures (Simply Natural Dentures [Glidewell Dental Laboratories]) that would fit properly and occlude functionally. Utilizing recorded bases with corresponding wax rims, we analyzed the positioning of the teeth and proper proportions for an ideal smile. The patient desired to have his new set of teeth with shade B-1 (VITA Shade Guide [Vident]). When the patient viewed the waxed try-in, he quickly approved them for processing (Figure 2).
Palpation and radiographic examination revealed a moderately narrowed mandibular ridge (Figure 3). Crestal bone and ridge height were sufficient to receive four 3 mm x 13 mm Inclusive Mini Dental Implants (Glidewell Direct) (Figure 4). The thread pattern and pitch of this implant are purposely designed to immediately maximize bone-to-implant thread contact. (Others like it include: I-Mini [OCO Biomedical], I6B [AB Dental USA], HM [Hiossen], Milo [Intra-Lock], MIDI [Basic Dental Implants], Intermezzo [Mega’Gen], and MiniMark [ACE Surgical].)
After reviewing the patient’s panoramic radiograph, the mental foramina were also located, and it was confirmed that the 4 mini-dental implants could be safely placed within the cuspid-to-cuspid area.
Implants Are Easy to Code: The Question is the Final Appliance! | ||||||||||||||||||||||||||||||
Tom M. Limoli Jr
|
Outline of Clinical Treatment
Before starting treatment, all the risks, benefits, and alternatives were reviewed with the patient. A clean operating environment was established, the patient was draped, and local anesthetic was administered. Then, an indelible marker was used to designate landmarks and areas of insertion.
Keeping correct alignment, a 1.5-mm pilot drill from the Inclusive Surgical Kit (Glidewell Direct) was placed into the sites and advanced to a depth of 15 mm, measuring from the tissue surface using a surgical motor (AEU-7000E [Aseptico]) with generous amounts of sterile water. This additional 2 mm was the same depth of the tissue height to bone. In other words, 13 mm for the osteotomy in bone and 2 mm for tissue thickness was created to place a 13-mm-long implant. Paralleling Pins (Salvin Dental) were placed in the sites of the osteotomies and an x-ray taken to check the angulations to ensure proper orientation among the implant sites. Using a rotary tissue punch, a 3.0 mm outline was created over the initial osteotomies and the tissue plugs removed with a serrated curette (Zoll Dental). The osteotomies were completed with the final drill (2.4 mm) included in the Inclusive Surgical Kit. Once the osteotomies were completed, four 3 mm x 13 mm Inclusive Mini Dental Implants were placed in the osteotomies, using an implant finger driver (Figure 5) until increased torque became necessary. The ratchet wrench was then connected to the adapter; and next the implants were torqued to final depth, reaching a torque level of 65 Ncm (Figure 6). A postoperative radiograph was taken of the implants before initiating the prosthetic phase of treatment.
Figure 5. The mini-dental implant on the plastic insertion driver. | Figure 6. Four mini-dental implants in place in the mandible. |
Figure 7. Quick-Up [VOCO America] was placed in recesses for housing pick-up. | Figure 8. Retentive housings, as picked up in the lower denture. |
At that point, the location of each implant was transferred to the denture using bite registration material (Take One Advance Bite Registration [Kerr]). These areas were relieved to a diameter of 5.0 mm, and the denture was then reseated passively, confirming adequate relief had been properly established.
A covering silicone (Fit Test C&B [VOCO America]) was used to cover any undercuts or interface of the implants, allowing only the o-ball of the implant to be exposed. This step prevented problems of the pick-up material locking around the implants. A female o-ring keeper cap (Inclusive) was then fitted over each implant. Retentive fit and mobility were again verified. Each o-ring would create a retentiveness of approximately 5 lbs. Since there were 4 implants with corresponding housings, the total amount of force needed to remove the prosthesis would be about 20 lbs.
The cleaned and dried recesses in the lower denture were filled with cold-cure acrylic (Quick-Up [VOCO America]) (Figure 7) and seated onto the implants, allowing it to polymerize. Upon setting, the lower denture was relieved of any excess flash, and the flange areas were relieved (Figure 8). Finally, postoperative instructions were reviewed with the patient regarding denture placement, removal, and oral hygiene.
The patient was extremely excited and pleased that his new dentures were now very retentive and functional.
CLOSING COMMENTS
The advent of the mini-dental implant has given general dentists an efficient and less costly way of solving many of the challenges associated with complete dentures. In providing mini-dental implants that immediately improve denture function and retention, the clinician can rapidly restore a patient’s confidence and also yield positive economic benefits for the practice. In addition, the simplified protocols, conservative procedures, and elimination of gingival surgery make mini-dental implants ideal for medically, anatomically, and financially compromised patients.
It has been estimated that more than 36 million patients in the United States have lost their teeth; however, only one half of 1% have received implant therapy. This striking disparity signifies a huge untapped market for implants and dentures.
Dr. Nazarian maintains a private practice in Troy, Mich, with an emphasis on comprehensive and restorative care. He is a Diplomate in the International Congress of Oral Implantologists and is director of the Reconstructive Dentistry Institute. He has conducted lectures and hands-on workshops on aesthetic materials and dental implants throughout the United States, Europe, New Zealand, and Australia. Dr. Nazarian is also the creator of the DemoDent patient education model system. His articles have been published in many dental publications. He can be reached at (248) 457-0500 or at aranazariandds.com.